Aqueous Ammonia Injection Nozzles

Custom Solutions Bulletin 109
Application #090811
Industry: Utilities
Application: Aqueous Ammonia Injection for Selective Catalyst Reduction (SCR)
Product Description: SpiralAir with Protection Air Shroud

Situation:

The customer, a power plant OEM, had a preliminary specification for a coal-fired power plant SCR system. They wanted to spray 0.57 gpm (2.16 L/min) to 0.62 gpm (2.35 L/min) of a 29% aqueous ammonia solution into the power plant flue gas stream to control NOx emissions. The available air pressure was up to 80 psi (5.5 bar). Droplet size was to be minimized to ensure complete evaporation. The material of construction requested was 316 stainless steel. The lances were to have a 8" 150# mounting flange. Because this was a preliminary specification, the OEM requested two options, a straight-line configuration as well as a right-angle configuration.

Solution:

The BETE SpiralAir 101 provided the exact flow rates needed at 80 psi (5.5 bar) of atomizing air and a liquid pressure of 82 to 87 psi. The spray angle of 15-20 degrees was optimal to prevent spray from hitting the walls of the duct and the Sauter mean droplet size range around 25 microns to allow for complete evaporation. Because this was a custom solution, BETE was able to design to whatever protection air flow rate was required.

To discuss your fluid-related challenge, please contact BETE Applications Engineering at 413-772-0846 or appeng@bete.com.